Welcome to RECA Germany For trade customers only
Konfix pro firestop collars

For detailed information, other images and documents, please select individual articles from the following table.

Konfix pro firestop collars

See product details

Available in 2 versions

Prices for customers after login

Exclusively for trade customers

Register now and access more than 40,000 products

Variants

Exclusively for trade customers

Register now and access more than 40,000 products

Call customer service: 0800 7322667

Prices for customers after login


The Konfix pro fire protection collars are used to seal disposal pipes in mixed installations consisting of cast-iron pipes that transition to combustible pipes.

Application area:


The Konfix Pro fire protection collar is designed for sealing cast iron disposal pipes, which are key elements in wastewater systems. The fire protection collars are installed where the system transitions to combustible pipes (mixed installation) in accordance with the specifications of DIBt (Deutsches Institut für Bautechnik - German Institute for Construction Technology) (DIBt Newsletter 02/2012 "Metal pipes with connection to plastic pipes").

Field of Application:


Approved installations:
Cast iron pipes connected to plastic branch pipes
- Cast iron (main pipes) up to 160 mm in outer diameter
- Branch pipes up to 110 mm in diameter made of PVC, PP, PE-HD, LDPE, PB, PE-X, ABS, ASA
- Sound-absorbing wastewater pipes: Friatec Friaphon, Ostendorf Skolan, Geberit Silent-db20/PP/Pro, Rehau RAUPIANO PLUS/LIGHT, Wavin AS+/SiTech+, Poloplast POLO-KAL 3S/XS/NG, CONEL DRAIN, Pipelife Master 3 and many more
- Deep branches possible (measured from bottom edge of ceiling), depths of 90 mm or more
- Sealing ceilings made of reinforced concrete, concrete and autoclaved aerated concrete with a thickness that is larger than or equal to 150 mm (fire resistance class F90 in accordance with DIN 4102-04)
- The seal must be behind a weather-facing layer measuring at least 12.5 mm in thickness with non-combustible construction panels bound in cement or plaster. Alternatively, the seal must be in solid materials measuring at least 50 mm in thickness
- Also approved even where there is insulation or sheathing in the ceiling opening (see proof of use)


Advantages:


25-year manufacturer's warranty
Retrofitting to standard Konfix connectors and clamping connectors
Sealing to other seals (supply and ventilation seals) with zero clearance possible
The DN 100 collar can also be used on the DN 70, DN 75 and DN 80 pipe connectors by breaking off three fire protection shaped parts.

Included in delivery:


Konfix Pro fire protection collar
Clamp
Identification plate
Installation instructions

Advice:


Please observe the respective proof of usability before use and fit according to specifications!