For detailed information, other images and documents, please select individual articles from the following table.
Available in 3 versions
Prices for customers after login
Register now and access more than 40,000 products
Variants
Register now and access more than 40,000 products
Application area:
Multiple attachment of non-load-bearing systems with approval
In cracked concrete (concrete tension zone) and uncracked concrete (compression zone)
E.g. lightweight ceiling cladding and suspended ceilings, pipes, cable trays, metal profiles, perforated strips, wire hangers, vernier hangers, wooden strips, wooden slats, square timbers etc.
For use in reinforced or non-reinforced standard concrete with a concrete compressive strength of min. C12/15 and max. C50/60 in accordance with EN 206-1:2000-12
May only be used in dry indoor room conditions
Field of Application:
Suspended ceilings, pipes, cladding, cable trays
Advantages:
The nail anchor offers the benefits of a stud anchor while also being easy to install; the nail anchor is simply knocked into the drill hole through the attachment. No subsequent torque is required, not even for the threaded version.
Quick and easy installation
- Less drilling required thanks to reduced effective anchorage depth of 25 mm
- Easy insertion: Simply hammer in - no torque required
- No special drills or setting tools required
In-place installation
Minimal spacing and edge distance
Elegant, attractive design
Load-controlled expansion anchor. Expands when subjected to load
Advice:
- Anchors in a redundant non-structural system in concrete: European Technical Assessment ETA-11/0240
- Fire resistance: R30, R60, R90, R120 (base material: concrete C20/25 to C50/60): Technical Report TR 020 "Evaluation of anchorages in concrete concerning resistance to fire" (included in ETA-11/0240)
Select RAL-colour code
!! NOTE: On-screen visualisation of the colour differs from real colour shade!!